About 76,500 results
Open links in new tab
  1. Introduction to Modbus and Modbus Function Codes

    Jan 30, 2023 · Introduction to Modbus and Modbus Function Codes Modbus is one of the oldest industrial communication protocols still in use today. Continue reading to find out how the …

  2. Modbus: The Original Industrial Fieldbus Protocol

    Sep 2, 2025 · This article introduces Modbus, an industrial protocol that laid the foundation for fieldbus communication in industrial systems.

  3. Introduction to Modbus | Digital Data Acquisition and Networks in ...

    Modbus data frames The Modbus communication standard defines a set of commands for reading (receiving) and writing (transmitting) data between a master device and one or more slave …

  4. Modbus client application | Automation & Control Engineering …

    Jan 9, 2024 · Open Modbus adds two other IEEE754 32 bit floating formats with its LE button which selects between Big Endian and Little Endian. Win-tech two standard FP formats …

  5. Modbus over Ethernet | Automation & Control Engineering Forum

    Jun 25, 2008 · Modbus is a protocol. You can use Modbus protocol over Ethernet, it is then called Modbus TCP/IP. Commonly used by Schneider Electric, as Schneider bought the company …

  6. Modbus RTU illegal data address - Control.com

    Sep 5, 2018 · I have 2 PLC controllers and in one controller I have Mapped variables to address 400001, 400002, 400004 and 400005 respectively and 400003 is not mapped. From Master if …

  7. Confused: Modbus TCP vs. Modbus RTU Over TCP - Control.com

    May 19, 2011 · Modbus RTU over TCP/IP is typically used by serial servers where you can have an Modbus Ethernet client communicating with multiple Modbus RTU- RS485 slaves, by way …

  8. How to find unknown Slave id on MODBUS Serial Communication

    Feb 9, 2025 · Since the sensors were connected via daisy chain, only one comm port was in use, so all the sensors used the same serial comm settings, baud rate, parity, stop bit. So what …

  9. Timeout error | Automation & Control Engineering Forum

    Feb 10, 2025 · Modbus Poll is a Modbus master simulator. If your ESP32 is indeed a master, then this won't work, as a Modbus master cannot communicate to another Modbus master.

  10. Modbus TCP cable | Automation & Control Engineering Forum

    Jan 15, 2025 · Hello, Is it possible to run Modbus TCP protocol if cable lenght is 130-140m? It will work if I use cat6 instead of cat5? do you have experience with that?